PEL106 POWER ENERGY LOGGER Loggers
Product Description Highlights • IP67 all-terrain casing resistant to shock, UV light and high temperatures• Communication via Wifi, 3G-UMTS/GPRS, LAN (Ethernet), Bluetooth and USB• Self-powered via its voltage inputs up to 1,000 V• Continuous recording with an interval of 200 ms between measurements• Measurements as per the IEEE 1459 standard• 4 voltage inputs & 4 current inputs• Ideal for installation on electricity poles Description The PEL106 power logger measures and records all the useful data for energy consumption diagnostics. The PEL106 can be used without cutting off the mains power supply. ErgonomicsRugged thanks to its IP67 all-terrain casing, the PEL106 can be transported anywhere. It is equipped with 4 voltage channels and 4 current channels. No more battery problems: this logger is self-powered directly via the phase. The LCD screen with backlighting and a quadruple digital display is particularly easy to read. The PEL 106 is equipped with an SD/SD-HC card for backup of the data from several months or even years. MeasurementsSuitable for all types of electrical networks, the PEL106 automatically recognizes the sensors connected. It measures voltage up 1,000 VAC/VDC and current up to 10 kVAC / 5 kVDC. Its wide measurement ranges enable it to record power values up to 10 GW/Gvar/GVA, and energy up to 4 EWh/EVAh/Evarh. It is equipped with an Alarm mode. The user can define limits and a list of events is recorded. Analogue measurementsWhen used with remote L452 loggers, the PEL106 can recording external parameters such as the temperature, pressure, engine torque, etc., and thus refine the analysis if you are troubleshooting malfunctions, for example. This function on the PEL106 is ideal for applications involving new energies such as wind (electrical energy linked to the strength of the wind). Ultra-communicatingThe PEL106 is equipped with multiple communication modes: USB, Ethernet, Bluetooth, Wifi and 3G/GPRS. The new 3G/GPRS mode allows users to insert a SIM card in the PEL for remote connection via a GSM. When an alarm is triggered, users can automatically receive an email alert.When access to the PEL106 is complex due to protective measures on secure IT networks, the measurements can be viewed via an IRD server. SoftwareThe PEL Transfer software can be used to analyse the data recorded with the PEL100 models. On the basis of the power measurement campaigns performed, the software automatically provides a breakdown of the losses detected.New: the software directly calculates the cost of the power consumed and gives the result in the local currency selected. The DATAVIEW software platform can be used to generate reports. Users can set alarm thresholds on the various measurements made in order to obtain a customized measurement report. Additional specifications:Acquisition interval from 200msVoltages, currentActive, apparent and reactive power valuesPhase: cos phi, tan PHI, PFTHD Harmonics IP67 closed, IP54 open Download Brochure / Specifications : PEL100 Specifications Download
PEL 105 Logger Loggers
Product Description Chauvin Arnoux Model PEL 105 is a simple to use, power and energy data logger that monitors both traditional and renewable energy sources. It monitors and records True RMS voltage and current, power, energy, cost and harmonics locally or from anywhere in the world. The PEL 105 is built into a waterproof case with an IP67 rating designed for outdoor use and is ideal for pole mounting and can be powered from a phase being monitored. This product is perfect for electricians, engineers and contractors doing work in the areas of building and system monitoring and upgrades, including compliance to article 220.87 of the NEC, as well as overall energy audits and incoming power monitoring. It is available with an Android™ App to configure, view and capture data wirelessly. Bluetooth and Wi-Fi wireless communication provides the operator with the ability to work from a safe distance away from dangerous voltages and currents. Advantages 5 voltage inputs & 4 current inputs All-terrain shockproof casing resistant to UV light and high temperatures Ideal for mounting on electricity poles Self-powered by its voltage inputs up to 1,000 V Continuous recording at 200 ms intervals Measurements in compliance with IEEE 1459 Inputs  5 Voltage / 4 Current Sample Rate 128 per Cycle 6.4kHz at 50Hz 7.68kHz at 60Hz Specification Range Measurement Range Resolution Accuracy (Typical) Volt Vrms 1000V P to N 10 to 1000V 0.1V ±0.2% Rdg +0.2V Vrms 1000V E to N 10 to 1000V 0.1V ±0.2% Rdg +0.2V Urms 1000V P to P 17 to 1000V 0.1V ±0.2% Rdg + 0.4V Amps @ 50 and 60Hz Amps (1V nominal)(excluding clamp accuracy Probe dependent 0.2%< I < 120% Inom Probe dependent ±0.2% Rdg + 0.02% Inom AmpFLEX & MiniFlex (including sensor accuracy) Range 100A Range 400ARange 2kARange 10kA 200mA to 120A5 to 440A50 to 2400A400A to 12kA 1mA0.1A0.1A & 1A1A ±1.2% Rdg + 50mA±1.2% Rdg + 0.2A±1.2% Rdg + 1A±1.2% Rdg + 5A Frequency   42.5 to 69Hz 0.01Hz ±0.1Hz Power Watts (VA, var) P-Q-S 20W to 20GW / 20var to 10Gvar / 20VA to 10GVA 4 digits min ±0.5% Rdg + 0.005% Pnom Power Factor (Cos Φ/DPF) -1  to 1 0.001 ±0.05 Energy kWh (kVAh, kvarh) P-Q-S Up to 4EWh / 4Evarh / 4 EVAh (E = 1018 ) ±0.5% Rdg Harmonics DC, 1 to 50 Volts & Amp %   0.01 to 655.0% 0.01% ±1% Rdg from 1 to 25 THD   0.00 to 655.0% 0.01% ±1% Rdg General Features Case Design Rugged field case Interface Isolated USB, Bluetooth, and Ethernet, Wi-Fi, SD card for direct transfer to PC. Dataview software for real time data, configuration and reporting included Memory 8GB SD card (SDHC compliant, FAT32 formatted)  32GB max Display LCD with backlight 4.2 x 3.3” (107 x 84mm) Real-Time Clock Time and date stamp for Trend mode Power Phase to phase or phase to neutral 100 to 1000VAC or external power pack 110V/230V 50/60Hz 15VA; Battery backup when power OFF, 60 minutes typical Dimensions (L x W x H) 9.65  x 10.6 x 7.1” (245 x 270 x 180mm) Weight 8.9 lbs (4kg) Altitude Operating 2000m (6560ft) Operating Temperature 32° to 108.5°F; (0° to +42.5°C) from 10 to 85% RH Storage Temperature -4° to 122°F; (-20° to +50°C) from 0 to 75% RH with battery pack Electro-Magnetic-Compatibility (EMC) EN 61326-1 for emission and immunity IP Rating IP 67 per IEC 60529 Safety IEC/EN 61010-1 (1000V CAT IV Pol 4) Download Specifications : Click Here
PEL103 POWER-ENERGY LOGGER Loggers
Product Description The PEL 103 is a low cost, simple to use, one, two (split phase) and three phase power/energy data logger. This product is ideal for electricians, engineers and contractors doing work in the area of building and system monitoring and upgrades, as well as residential and overall energy audits. All vital energy data is easily measured, recorded, and analyzed. Reports can be generated with confidence with minimal configuration time and effort (Standard and Customizable Reports supplied). The instrument’s design enables it to be installed inside a load center panel (including the current sensors) allowing the door to close on most panels. The PEL 100 series offers all the essential functions for logging power/energy data from most electrical power networks in use today across the world (17 network set-ups provided). The PEL 100 series energy loggers measure and record three True RMS voltage inputs and current inputs, Watts, VARS, VA and Energy (kWh and kVA). Power Factor (PF), Displacement Power Factor (DPF), Crest Factor, Frequency and THD are calculated and recorded as well. Individual harmonic % information from 1 to the 50th harmonic are recorded at the operator’s choice. All variables are recorded and stored at a one second interval and on user selectable demand intervals from 1 to 60 minutes. The PEL 103 comes either with or without sensors, see model options and descriptions below. Ergonomic, magnetized and suitable for all types of cabinets, PEL103 loggers provide all the power and energy measurements simultaneously. Single-phase, split-phase and three-phase installations with or without a neutral, as well as other complex configurations. Implementation without cutting off the mains power supply BlueTooth, Ethernet and USB communication Automatic recognition of the sensors connected Recording on SD and SD-HC cards Real-time communication with a PC and analysis using PEL Transfer software Other specifications: Voltage up to 1,000 V Current up to 10,000 A Voltage ratio / current ratio up to 650,000 V / up to 25,000 A Power from 10 W/var/VA to 10 GW/Gvar/GVA Energy up to 4EWh / 4 EVAh / 4 Evarh Phase: cos φ, tan Φ, PF Harmonics up to 50th order 2 GB SD memory card (SD-HC card up to 32 GB) Specifications Inputs  3 Voltage / 3 Current: calculation of neutral current Sample Rate 128 per Cycle 6.4kHz at 50Hz 7.68kHz at 60Hz Specification Range Measurement Range Resolution Accuracy (Typical) Volt Vrms 1000V P to N 10 to 1000V 0.1V ±0.2% Rdg + 0.2V Urms 1000V P to P 17 to 1700V 0.1V ±0.2% Rdg + 0.4V Amps @ 50 and 60Hz Amps (1V nominal)(excluding clamp accuracy Probe dependent 0.2%< I < 120% Inom Probe dependent ±0.2% Rdg + 0.02% Inom AmpFLEX & MiniFlex (including sensor accuracy) Range 100A Range 400ARange 2kARange 10kA 200mA to 120A5 to 440A50 to 2400A400A to 12kA 1mA0.1A0.1A & 1A1A ±1.2% Rdg + 50mA±1.2% Rdg + 0.2A±1.2% Rdg + 1A±1.2% Rdg + 5A Frequency   42.5 to 69Hz 0.01Hz ±0.1Hz Power Watts (VA, var) P-Q-S 10W to 10GW / 10var to 10Gvar / 10VA to 10GVA 4 digits min ±0.5% Rdg + 0.005% Pnom Power Factor (Cos Φ/DPF) -1  to 1 0.001 ±0.05 Energy kWh (kVAh, kvarh) P-Q-S Up to 4EWh / 4Evarh / 4 EVAh (E = 1018 ) ±0.5% Rdg Harmonics DC, 1 to 50 Volts & Amp %   0.01 to 655.0% 0.01% ±1% Rdg from 1 to 25 THD   0.00 to 655.0% 0.01% ±1% Rdg General Features Case Design Rugged, shock proof with integrated protective holster, IP54 not included terminals. Shock and vibration IEC61010 Interface Isolated USB, Bluetooth, and Ethernet, SD card for direct transfer to PC. Dataview software for real time data, configuration and reporting included Memory 8GB SD card (SDHC compliant, FAT32 formatted)  32GB max Display LCD with backlight Real-Time Clock Time and date stamp for Trend mode Power AC 110V/230V 50/60Hz 15VA; Battery backup when power OFF, 60 minutes typical Dimensions (L x W x H) 10.08 x 4.92 x 1.46” (256 x 125 x 37mm) Weight 2.2lbs (1kg) Altitude Operating 2000m (6560ft) Operating Temperature 32 to 108.5°F; (0°C to +42.5°C) from 10 to 85% RH Storage Temperature -4 to 122°F; (-20°C to +50°C) from 0 to 75% RH with battery pack Electro-Magnetic-Compatibility (EMC) EN 61326-1 for emission and immunity IP Rating IP54 per IEC 60529 Safety IEC/EN 61010-1 (1000V CAT III-600V CAT IV), IEC 1326-1 Download Specifications : Click Here
PEL102 POWER-ENERGY LOGGER Loggers
Advantages Single-phase, split-phase and three-phase installations with or without a neutral, as well as other complex configurations. Implementation without cutting off the mains power supply BlueTooth, Ethernet and USB communication Automatic recognition of the sensors connected Recording on SD and SD-HC cards Real-time communication with a PC and analysis using PEL Transfer Description Ergonomic, magnetized and suitable for all types of cabinets, PEL102 loggers provide all the power and energy measurements simultaneously. Other specifications: Voltage up to 1,000 V Current up to 10,000 A Voltage ratio / current ratio up to 650,000 V / up to 25,000 A Power from 10 W/var/VA to 10 GW/Gvar/GVA Energy up to 4EWh / 4 EVAh / 4 Evarh Phase: cos φ, tan Φ, PF Harmonics up to 50th order 2 GB SD memory card (SD-HC card up to 32 GB)