PEL103 POWER-ENERGY LOGGER Loggers
Product Description The PEL 103 is a low cost, simple to use, one, two (split phase) and three phase power/energy data logger. This product is ideal for electricians, engineers and contractors doing work in the area of building and system monitoring and upgrades, as well as residential and overall energy audits. All vital energy data is easily measured, recorded, and analyzed. Reports can be generated with confidence with minimal configuration time and effort (Standard and Customizable Reports supplied). The instrument’s design enables it to be installed inside a load center panel (including the current sensors) allowing the door to close on most panels. The PEL 100 series offers all the essential functions for logging power/energy data from most electrical power networks in use today across the world (17 network set-ups provided). The PEL 100 series energy loggers measure and record three True RMS voltage inputs and current inputs, Watts, VARS, VA and Energy (kWh and kVA). Power Factor (PF), Displacement Power Factor (DPF), Crest Factor, Frequency and THD are calculated and recorded as well. Individual harmonic % information from 1 to the 50th harmonic are recorded at the operator’s choice. All variables are recorded and stored at a one second interval and on user selectable demand intervals from 1 to 60 minutes. The PEL 103 comes either with or without sensors, see model options and descriptions below. Ergonomic, magnetized and suitable for all types of cabinets, PEL103 loggers provide all the power and energy measurements simultaneously. Single-phase, split-phase and three-phase installations with or without a neutral, as well as other complex configurations. Implementation without cutting off the mains power supply BlueTooth, Ethernet and USB communication Automatic recognition of the sensors connected Recording on SD and SD-HC cards Real-time communication with a PC and analysis using PEL Transfer software Other specifications: Voltage up to 1,000 V Current up to 10,000 A Voltage ratio / current ratio up to 650,000 V / up to 25,000 A Power from 10 W/var/VA to 10 GW/Gvar/GVA Energy up to 4EWh / 4 EVAh / 4 Evarh Phase: cos φ, tan Φ, PF Harmonics up to 50th order 2 GB SD memory card (SD-HC card up to 32 GB) Specifications Inputs  3 Voltage / 3 Current: calculation of neutral current Sample Rate 128 per Cycle 6.4kHz at 50Hz 7.68kHz at 60Hz Specification Range Measurement Range Resolution Accuracy (Typical) Volt Vrms 1000V P to N 10 to 1000V 0.1V ±0.2% Rdg + 0.2V Urms 1000V P to P 17 to 1700V 0.1V ±0.2% Rdg + 0.4V Amps @ 50 and 60Hz Amps (1V nominal)(excluding clamp accuracy Probe dependent 0.2%< I < 120% Inom Probe dependent ±0.2% Rdg + 0.02% Inom AmpFLEX & MiniFlex (including sensor accuracy) Range 100A Range 400ARange 2kARange 10kA 200mA to 120A5 to 440A50 to 2400A400A to 12kA 1mA0.1A0.1A & 1A1A ±1.2% Rdg + 50mA±1.2% Rdg + 0.2A±1.2% Rdg + 1A±1.2% Rdg + 5A Frequency   42.5 to 69Hz 0.01Hz ±0.1Hz Power Watts (VA, var) P-Q-S 10W to 10GW / 10var to 10Gvar / 10VA to 10GVA 4 digits min ±0.5% Rdg + 0.005% Pnom Power Factor (Cos Φ/DPF) -1  to 1 0.001 ±0.05 Energy kWh (kVAh, kvarh) P-Q-S Up to 4EWh / 4Evarh / 4 EVAh (E = 1018 ) ±0.5% Rdg Harmonics DC, 1 to 50 Volts & Amp %   0.01 to 655.0% 0.01% ±1% Rdg from 1 to 25 THD   0.00 to 655.0% 0.01% ±1% Rdg General Features Case Design Rugged, shock proof with integrated protective holster, IP54 not included terminals. Shock and vibration IEC61010 Interface Isolated USB, Bluetooth, and Ethernet, SD card for direct transfer to PC. Dataview software for real time data, configuration and reporting included Memory 8GB SD card (SDHC compliant, FAT32 formatted)  32GB max Display LCD with backlight Real-Time Clock Time and date stamp for Trend mode Power AC 110V/230V 50/60Hz 15VA; Battery backup when power OFF, 60 minutes typical Dimensions (L x W x H) 10.08 x 4.92 x 1.46” (256 x 125 x 37mm) Weight 2.2lbs (1kg) Altitude Operating 2000m (6560ft) Operating Temperature 32 to 108.5°F; (0°C to +42.5°C) from 10 to 85% RH Storage Temperature -4 to 122°F; (-20°C to +50°C) from 0 to 75% RH with battery pack Electro-Magnetic-Compatibility (EMC) EN 61326-1 for emission and immunity IP Rating IP54 per IEC 60529 Safety IEC/EN 61010-1 (1000V CAT III-600V CAT IV), IEC 1326-1 Download Specifications : Click Here