TBL5032-3 50uH Line Impedance Stabilisation Network LISN – CISPR 16
General Test Equipment
Product Description
TBL5032-3 50uH Line Impedance Stabilisation Network LISN – CISPR 16
The TBL5032-3 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9 kHz to 30MHz, according to the CISPR 16-1-2 standard. The device is designed for testing 3-phase and single phase, AC-powered equipment with supply voltages up to maximum 450V/260V and 32A. Conducted noise can be measured on each phase and on the neutral conductor. The TBL5032-3 has separate RF outputs for each phase and neutral and consequently can be coupled with the TBLM1 to split the emissions in its common mode and differential mode components. The TBL5032-3 has no integrated high pass filter at the RF outputs, but comes with an external 9 kHz coaxial high pass instead.The single-phase DUT socket is available in country-specific variants.
SPECIFICATIONS
Frequency range: 9 kHz to 30 MHz
Impedance: 50 Ω ║ (50 µH + 5 Ω)
Artificial hand: 220 pF + 511 Ω
Switchable PE: 50 Ω ║ 50 µH
250µH pre-filter
Separate RF outputs for each line and neutral
Air core inductors
Line voltage: max. 540V/260V / 50 – 60 Hz, CAT ‖
Max. current per line and neutral: 32A @ 23°C each
3-phase DUT socket: CEE/IEC60309, 3L+N+PE, 32A, female
Single-phase DUT socket: country specific
Power connector: CEE/IEC60309, 3L+N+PE, 32A, male
Measurement connectors: 50 Ω BNC
External 9 kHz high pass filter, N-male / N-female
Operating Temperature Range: +5°C … + 40°C; 5% to 80% RH
APPLICATION
EMC conducted noise measurements
Please click here for : Specifications
TBL5016-1 50uH 16A Line Impedance Stabilisation Network LISN
Oscilloscope Accessories
Product Description
The TBL5016-1 50µH LISN is a device required to setup conducted noise measurements of DC or AC-powered electronic equipment. It is designed according to CISPR 16-1-2 and MIL-STD-461F standard and characterized in the frequency range of 9kHz to 100 MHz.
Apart from carrying out conducted noise measurements, LISNs are also used to establish a defined impedance for various other standardized tests.
The LISN is a 50Ω/50µH+5 Ω single line design with a high current jumper to short the 5 Ohm resistor and configure it as 50Ω/50µH LISN according to CISPR 16-1-2. The LISN is characterized up to 100 MHz which means that the LISN can be used for the combined range of 9 kHz to 100 MHz.
The LISN is inserted into the supply line of the DUT (Device Under Test). Conducted noise, which is present at the supply terminals of the DUT can be measured at the BNC connector using a spectrum analyzer or a measurement receiver. The source (supply) terminal and the DUT terminal are decoupled by a 50µH inductor. DC or single phase measurements typically require a pair of TBL5016-1. Combining it with the Tekbox LISN Mate enables separate measurement of common mode and differential mode noise. DUTs with 3 phase supply require three or four pieces of TBL0516-1, depending on whether the product is supplied in delta or star configuration.
The unit comes equipped with a BNC-male to N-male RG232 cable, mating connectors, high current configuration jumpers and ground brackets to attach it to a ground plane.
Specifications
LISN type: V-AMN, configurable as 50Ω/50µH+5 Ω or 50Ω/50µH
Frequency range: 9 kHz – 100 MHz
DC Resistance: < 45 mΩ
Maximum current: 16A continuous
Operating voltage range: 0 – 250V DC; 0 – 250V AC (50/60 Hz), 0 – 120V AC (400 Hz)
Fuse: 2 x 16A slow
High current plug/screw terminals – male: Phoenix Contact 1998933, female: Phoenix Contact 1967375
Dimensions: 250 mm x 225 mm x 140 mm (including ground brackets)
weight: 2.7 kg