MonitEM-Lab Indoor RF monitoring Wavemon Area Monitors
MonitEM-Lab Indoor RF monitoring  24/7 Monitoring Permanent around the clock monitoring Alarms Realtime, audible and visual alarms Broadband measurement For an easy indoor RF monitoring of human exposure Compliance with ITU-T K.83 Direct, easy and comprehensible comparison with regulated limits Control center Optional software for system management MonitEM_Lab_Datasheet_EN.pdf     Compatible Field Probes   E (100 kHz - 60 GHz) H (300 kHz – 1000 MHz) RF Monitor overexposure alarms MonitEM-Lab can warn of a higher than expected electromagnetic field level in different ways: by sending an alarm to the control centre (to be received by the specified e-mail addresses), or by a sound alarm or a light alarm.All the alarms are built in, making the device compact with no need for external accessories. The alarm to the control center is transmitted via ethernet, the audible alarm is internal to the equipment, like the visible alarm, which noticeably illuminates the entire dome of the indoor RF (Radio frequency) monitoring equipment.  control center MonitEM devices can be optionally used together with a web server using software that is unique on the market and allows remote configuration and management of the monitoring equipment, data consultation and report generation, among other functions.       MANAGEMENT AND CONFIGURATION OF EQUIPMENT DATA RECEPTION, CONSULTATION AND STORAGE REPORT GENERATION AND AUTOMATIC DELIVERY DISPLAY OF PHOTOGRAPHS AND DIAGRAMS USER FRIENDLY, WITH GOOGLE MAPS POSITIONING Applications Defense Reference customers ITU-T K.83 Recommendation Monitoring of electromagnetic field levels. The ITU-T K.83 Recommendation provides guidelines for taking long-term measurements for control of electromagnetic fields (EMF) in selected areas of public interest, in order to show that those fields are under control and remain with the established limits. The aim of that Recommendation is provide the general public with clear and easily accessible information on electromagnetic fields set out in the form of the results of continuous measurement.
WaveMon RF-60 is a 5G-ready RF Personal Monitor (100 kHz to 60 GHz) Wavecontrol : RF safety / EMF safety
WaveMon RF-60 Personal RF Monitor ELECTRIC AND MAGNETIC FIELD DETECTION  Isotropic sensors with RMS response Weighted response to international standards  ICNIRP, European Directive 2013/35/EU, FCC, Safety Code 6 (2015) and NATO INSTANT AND AVERAGE VALUES  Alarms on instant and average values. Configurable EXPOSIMETER WITH DATALOGGER  Data collecting and Reporting GPS AND ALTIMETER  Geolocation of measurements HIGH INTENSITY AUDIBLE, VISIBLE AND VIBRATORY ALARM  With user definable trigger threshold USB COMMUNICATION PORT  Data downloading, set-up and battery charging WaveMon_RF-60_Datasheet_EN.pdf WEIGHTED RESPONSE   The WaveMon gives a specific weighted response for each standard. It is not just single model that attempts to follow all standards at once. Such an approach will always result in poorer accuracy. This is a weighted response, designed to follow the limits of the applicable standard, for greater accuracy. The following monitors are now available: WaveMon RF-60 ICN → ICNIRP version WaveMon RF-60 EUD → European Directive 2013/35/EU version WaveMon RF-60 FCC → FCC version WaveMon RF-60 SC6 → Safety Code 6 (2015) version WaveMon RF-60 NATO → NATO version If you need a personal radio frequency monitor that specifically follows some other standard, please let us know.   DATALOGGER   The WaveMon is a radio frequency exposimeter that have a datalogger for continuous data recording. Communication with the device is through a USB port that allows you to parametrise the device and download the recorded data. This makes it easy to create reports and allows you to keep a record of your exposure data for your safety.     PRACTICALITY   We have created an accessory that allows you to attach the personal RF monitor to your harness, arm or belt and so take it in hand to hold it near a radiation source and then put it back in place easily. You can also secure it with a small carabiner so that it won’t be dropped. BATTERIES   The device is small and lightweight and works with AA batteries that can be recharged via the USB port. It can also use standard AA batteries, so that they can always be easily replaced. Easy, isn’t it? Because we want you always to be protected. GPS AND ALTIMETER   The WaveMon is the only RF personal monitor equipped with a GPS and Altimeter for geolocation of measurements. As an example, in a telecommunication tower, the GPS will provide the geographical position of the tower and the Altimeter the relative height from the ground. Thus, the radio frequency monitor will record 'Exposure Level' together with 'Date', 'Time', 'Geographical Position' and 'Height' on the Tower, allowing you to perfectly locate the hotspots. ALARMS ON INSTANT AND AVERAGE VALUES   The WaveMon is the only personal RF monitor that can give alarms for average value and instantaneous value at the same time. Remember that internationally established exposure limits are specified as values averaged over a given time (e.g. 6 or 30 minutes). Some important examples include the limits established under ICNIRP, FCC, Safety Code 6, European Directive 2013/35/EU, etc. USER-CONFIGURABLE ALARMS   Over-exposure alarms can be configured from a PC with all their parameters. Two different alarms can be programmed and personalised separately. The following basic parameters can be personalised: Value type (generated by instantaneous or average value) Alarm level (% of limit) Type of alarm (sound, vibration or both) Low frequency immunity   Experience shows that personal RF monitors with poor immunity to low frequencies give false alarms near high-voltage lines or other types of powerful electric equipment. The WaveMon is the personal monitor with the best immunity and it can work in electric field intensity conditions of up to 30 kV/m at 50/60 Hz without giving false readings of non-existent RF levels. That is better, for example, than the occupational exposure limit under ICNIRP: 20 kV/m. RF ABSORTION   When the personal monitor is worn on the body, which is how it is most often used, reflections of electromagnetic fields from the body itself can affect the measurement and compromise its accuracy. The holder for the WaveMon includes an RF absorbent material to reduce that effect. When the device is in the holder, next to the body, the absorbent material is placed strategically between the sensor and the body, but when it is used away from the body, outside the holder, that material is not present and the WaveMon gives an undisturbed isotropic behaviour. Fully compliant with ITU-T K.145    The Recommendation ITU-T K.145, issued by the International Telecommunication Union, recommends that RF personal monitors (exposimeters) be equipped with a list of basic features in RF safety for RF workers worldwide. The WaveMon is fully compliant with this Recommendation. In addition, Wavecontrol is member of the National Association of Tower Erectors (NATE) in the US, organization promoting the highest standards of safety for Tower Climbers and RF Workers MAIN CHARACTERISTICS OF THE WAVEMON Conforms to international electromagnetic field safety standards E-field measurements up to 60 GHz and H-field measurements up to 1 GHz Isotropic sensors RMS detection Weighted response chosen from among ICNIRP, European Directive 2013/35/EU, FCC, Safety Code 6 (2015) and NATO, for direct comparison with the standard limit Instantaneous and average values, according to international standards High immunity at a 50/60 Hz: 30 kV/m User-configurable alarms High intensity audible, visible and vibration alarms Customisable alarm threshold Optional GPS and altimeter Datalogger to report and record data RF absorption to reduce reflections from the user’s body USB for PC connection to parameterise and download data Small and lightweight Powered by 2 standard disposable or rechargeable (via USB port) batteries Autonomy over 200 hours