WaveAce 1001 Oscilloscopes
WaveAce 100140 MHz, 500 MS/s, 2 ch, 1 Mpts/Ch, DSO with 7" Wide Display. 2 Mpts, 1 GS/s interleaved. 1 MOhm Key Features 40 MHz, 60 MHz, 70 MHz, 100 MHz, 200 MHz and 300 MHz bandwidths Sample rates up to 2 GS/s Long Memory - up to 1 Mpts/Ch (2 Mpts interleaved) Advanced Triggering - Edge, Pulse Width, Video, Slope (Rise Time) 7" wide screen display 32 automatic measurements Multi-language user interface and context sensitive help Four math functions and FFT USB host and device connections for printers, memory sticks and PC remote control Capture and View Waveform Details Long memory, high sample rate and easy to use zoom capabilities Automatic Measurements Measure with 32 different parameters including advanced timing measurements and a dashboard view Waveform Math and Analysis Basic math plus FFT for advanced waveform analysis Connectivity and Documentation Save waveforms, settings and screen captures to a USB device or directly to a PC Simple Pass/Fail Testing Quick mask testing with on screen result counter Record and Playback Waveforms Record and playback up to 2,500 waveform captures Custom Digital Filters Apply digital filters to isolate specific frequencies or eliminate noise Triggering A variety of basic and advanced triggering for capturing a range of different signals Save All Your Waveforms and Setups Save up to 20 waveforms and 20 setups to internal memory A Variety of Acquisiton Modes Chose from Real Time, Equivalent Time, Peak Detect and Averaging Specifications Vertical System Rise time 8.8 ns Bandwidth 40 MHz Input Channels 2 Bandwidth Limiters 20 MHz Input Impedance 1 MΩ ± 2% || 18 pF ± 3 pF Input Coupling AC, DC, GND Maximum Input Voltage ± 400 Vpk Channel-Channel Isolation ≥ 100:1 at 20 MHz Vertical Resolution 8 bits Sensitivity 2 mV/div - 10 V/div DC Gain Accuracy ±3%: 5 mV/div - 5 V/div (fixed gain ranges)±4%: 2mV/div and variable gain ranges Offset Range ±2 V: 2mV/div - 100 mV/div±40V: 102 mV/div - 5 V/div   Horizontal System Time/Division Range 10.0 ns/div - 50 s/div Clock Accuracy 100 ppm Trigger and Interpolator Jitter 2 ns (pk-pk)   Acquisition System Single-Shot Sample Rate/Ch 1 GS/s on 1 Ch500 MS/s on 2 Ch Equivalent Sample Rate 50 GS/s Memory 2 Mpt/Ch on 1 Ch1 Mpt/Ch on 2 Ch   Acquisition Modes Averaging Selectable Number of Sweeps:4, 16, 32, 64, 128, 256 Peak Detect 2.5 ns Interpolation Linear, Sin x/x Enhanced Resolution na Sequence Mode na   Triggering System Modes Normal, Auto, Single, Stop Sources Ch 1 - Ch 2, EXT, EXT/5, AC Line Coupling Mode AC, DC, LF Rej, HF Rej, Pre-trigger Delay memory/(2 * sample rate) Post-trigger Delay 260 Divisions Hold-off by Time or Events 100 ns - 1.5 s Internal Trigger Range ±6 divisions from center Trigger Sensitivity 1 division: DC - 10 MHz1.5 divisions: 10 MHz - 40 MHz External Trigger Sensitivity Ext: 200 mVpp from DC to 10 MHz300 mVpp from 10 MHz to 40 MHzExt/5: 1Vpp from DC to 10 MHz1.5 mVpp from 10 MHz to 40 MHz External Trigger Input Range Ext: ±1.2 V, EXT/5: ±6 V   Display Type Color 7.0 TFT-LCD Resolution Wide QVGA; 480 x 234 pixels Grid Styles YT (18 horizontal divisions), XY   Trigger Types Standard Triggers Edge, Pulse Width, Video, Slope (Rise Time), Alternate Optional Advanced Triggers na Optional Serial Data Triggers na   Internal Storage Waveform Storage 20 waveforms and 2 reference waveforms Setup Storage 20 setups   Math Number of Math Traces 1 Standard Math Functions Add, Subtract, Multiply, Divide, FFT Optional Math Functions na   Measurements Number of Measurements Displayed 5 Measurement Parameters Amplitude, Average, Base, Burst Width, Cyclical RMS, +Duty Cycle, -Duty Cycle, Fall Time, Frequency, Max, Mean, Min, Overshoot, Peak-Peak, Period, Phase, Preshoot, Rise Time, RMS, Top, +Width, -Width, First Rising-Rising, First Rising-Falling, First Falling-Rising, First Falling-Falling, Last Rising-Rising, Last Rising-Falling, Last Falling-Rising, Last Falling-Falling   Interface GPIB Port na USB (Device) 1 Ethernet Port na USB (Host) 1 Serial Port na   Probes Probes Qty. (2) ÷10/1 Passive Probes Scale Factors Manual: ÷1, ÷10, ÷100, ÷1000 Calibration Output 1 kHz square wave, 3Vp-p (typical), output to probe hook   Power Requirements Voltage 100 - 240 VAC, 45 Hz to 440 Hz Max. Power Consumption 50 VA   Environmental and Safety Temperature (Operating) 10 °C to 40 °C Temperature (Non-Operating) -20 °C to 60 °C Humidity (Operating) 95% RH, 40 °C Humidity (Non-Operating) 90% RH, 65 °C Altitude (Operating) 3000 m Altitude (Non-Operating) 15,266 m   Physical Dimensions Dimensions (HWD) 163 mm x 313 mm x 115.8 mm(6.42 x 12.32 x 4.6) Weight 2.78 kg (6.1 lbs)