C.A 852 Digital Manometer
Miscellaneous
Description
The C.A 852 Digital Manometer is ideal for measuring relative and differential pressure levels in air-conditioning installations, medical equipment and pneumatic control systems. The measurements are easy to read with its large display.Typical applications: measurement of filter clogging on air-conditioning installations, measurement of pressure losses in ventilation ducts, leakage tests in gas ducts, etc.
Measurement range: - 2 to + 2 psi
Maximum pressure: ± 20 psi
Resolution: 0.004 psi
Accuracy: ± 0.3 % full scale
Pressure units: bar, inH20, mmH2O, mbar
Functions
Time/date-stamped monitoring of MIN and MAX values
Differential pressure measurements
Measurement hold
Automatic power-off
Backlighting
Dimensions: 72 x 182 x 30 mm
Weight: 220 g
State at delivery
Delivered in carrying case with 2 connection pipes,1 operating manual in 5 languages and battery.
C.A 850- Digital Manometer
Miscellaneous
Description
The C.A 850 Digital Manometer is ideal for measuring relative and differential pressure levels in air-conditioning installations, medical equipment and pneumatic control systems. The measurements are easy to read with its large display.
Measurement range: -100 to +100 psi
Maximum pressure: ± 150 psi
Resolution: 0.01 psi
Accuracy: ± 0.3 % full scale
Pressure units: bar, mmHg, ozin², kg/cm², inH20, kPa, ftH2O, inHg, cmH2O, mbar
Functions
Time/date-stamped monitoring of MIN and MAX values
Differential pressure measurements
Measurement hold
Automatic power-off
Backlighting
Dimensions: 72 x 182 x 30 mm
Weight: 220 g
C.A 832-Sonometer
Miscellaneous
Description
In a compact case protected by a shockproof cover, the Physics Line C.A 832 digital sonometer checks sound levels from 35 to 130 dB in compliance with the IEC 651 type 2 standard.
Dynamic range: 37 to 130 dB
Accuracy: ± 1.5 dB
Resolution: 0.1 dB
Time weighting: Fast, Slow
Frequency weighting: dB(A) et dB(C)
Storage of maximum value
Analogue output: 10 mV/dB and 1 VRMS - 600 Ohms
Tripod insert
Shockproof protective sheath
Dimensions: 237 x 60.5 x 38 mm
Weight: 230 g
C.A 822-Thermo-anemometer
Miscellaneous
Description
In its rugged, ergonomic casing, the C.A 822 thermo-anemometer from the Physics Line range measures temperature and air speed very simply with its double display.
Temperature measurement range: - 20 to + 60 °C
Accuracy: 0.5 °C from 0 to 45 °C / 1 °C outside that range
Resolution: 0.1 °C
Air-speed measurement range: 0.4 to 30 m/s
Accuracy: 3 % full scale
Resolution: 0.01 m/s
Double display
Maximum value, minimum, average, Hold
Selection of measurement unit
Backlighting
C.A 847
Miscellaneous
Description
In a compact case protected by a shockproof sheath, the Physics Line C.A. 847 materials humidity indicator checks the humidity content from 6 to 100% in construction materials like plaster, wood, etc.
2 display scales with 20 LEDs: 6 to 23 % / 24 to 100 %
Integrated, replaceable electrodes (L = 12 mm)
Battery charge indication
Dimensions: 195 x 60.5 x 38 mm
Weight: 160 g
Shockproof sheath
C.A 1244- 3-in-1 instrument
Miscellaneous
Description
The C.A 1244 is a 3-in-1 instrument: measurement of humidity, ambient temperature and dew point.
Relative humidity: 5 to 95 % RH
Ambient temperature: - 20 °C to + 70 °C
Dew-point temperature: - 40 °Ctd à + 70 °Ctd
Choice of units
HOLD function
Display of minimum and maximum
Automatic calculation of the average
Adjustable automatic power-off
Adjustable backlighting
IP54
C.A 1226-Ventilation or air-conditioning systems
Miscellaneous
Description
The C.A 1226 can be used to check the operation of your ventilation or air-conditioning systems (at the outlet or in the ducts). Compact and easy to handle, it is equipped with a dual display so that you can simultaneously view two values chosen from the three measured: temperature, the speed and the flow rate.
Measurement of air speed, flow rate and ambient temperature
Speed: 0.15 to 3 m/s and 3.1 to 30 m/s
Flow rate: 0 to 99,999 m3/h
Temperature: - 20 to + 80 °C
Choice of units
HOLD function
Display of minimum and maximum
Automatic calculation of the average
Flow-rate calculation with or without cone
Adjustable automatic power-off
Adjustable backlighting
C.A 1224- Ventilation and air-conditioning installations
Miscellaneous
Description
Ergonomic and simple to use, the C.A 1224 can be used to check the operation of your ventilation and air-conditioning installations.It is equipped with a dual display so that you can simultaneously view two values chosen from the three measured: temperature, the speed and the flow rate.
Measurement of air speed, flow-rate and ambient temperature
Speed: 0.25 to 3 m/s and 3.1 to 35 m/s
Flow rate: 0 to 99,999 m3/h
Ambient temperature: - 20 to + 80 °C
Choice of units
HOLD function
Display of minimum and maximum
Automatic calculation of the average
Flow-rate calculation with or without cone
Adjustable automatic power-off
Adjustable backlighting
C.A 1052
Miscellaneous
Description
Delivered in a rugged hard case with all its probes, the C.A 1052 multi-function tester offers a large number of possibilities:
Automatic recognition of the probess
Speed (vane and hot wire) and ambient temperature measurement
Relative humidity measurement
Pressure measurement
Temperature measurement by contact
Choice of units
HOLD function
Display of minimum and maximum
Automatic calculation of the average for any type of measurement
Flow-rate calculation with or without cone
Recording of up to 8,000 points
Data processing software supplied as standard
Adjustable automatic power-off
Adjustable backlighting
C.A 895
Miscellaneous
Description
In a compact casing protected by a shockproof sheath, the Physics Line C.A 895 CO-gas detector detects and measures carbon monoxide.
2 measurement modes: “normal” for detection of a source of CO “average” for precise measurement
Measurement range: 0 to 1,000 ppm
Accuracy: ± (5 % of reading + 5 ppm)
“Beeper” indicating the hazard level (same principle as a Geiger counter)
Storage of maximum value
Hold function
Dimensions: 237 x 60.5 x 38 mm
Weight: 190 g
C.A 833 Calibrator (Calibrating sound level meters).
Miscellaneous
Description
The C.A 833 Calibrator is a standard source (1kHz) used for calibrating sound level meters.
Compliant with the IEC 942 type 2 standard
Calibration level: 94 and 114 dB
Usable microphone diameter: 2.5 cm / 1.3 cm / 0.64 cm
C.A 813
Miscellaneous
Description
Protected by a shockproof sheath in a compact case, the Physics Line CA 813 lightmeter measures lighting between 20 and 200,000 lux.
Measurement range from 0 to 200,000 lux
Accuracy ± (3 % of reading + 10 points)
Resolution from 0.01 lux
I.E.C. spectral correction and incidence correction
Remote probe which limits the risk of the operator shading the sensor
Hold / Backlighting / Lux or fc / Max
Shockproof protective sheath
Dimensions: 173 x 60.5 x 38 mm
Weight: 214 g
C.A 811
Miscellaneous
Description
Protected by a shockproof sheath in a compact case, the Physics Line CA 811 lightmeter measures lighting between 20 and 20,000 lux.
Measurement range from 0 to 20,000 lux
Accuracy ± (3 % of reading + 10 points)
Resolution from 0.01 lux
I.E.C. spectral correction and incidence correction
Remote probe which limits the risk of the operator shading the sensor
Hold / Backlighting / Lux or fc / Max
Shockproof protective sheath
Dimensions: 173 x 60.5 x 38 mm
Weight: 214 g