C.A 6471 Earth Tester
Ground Resistance Testers
Product Description
Earth tester offering selective earth, soil resistivity, earth coupling and continuity measurementsErgonomic, comprehensive and accurate, the C.A 6471 offers direct access to all the measurements on the front panel by means of a rotary switch. Compact because it has been designed for on-site use, the C.A 6471 is rugged and leakproof. To simplify connection, the 4 terminals for connecting the stakes are colour-coded to help identify them. The C.A 6471 includes a large backlit LCD screen and a battery which is rechargeable with an external charger connected to the mains or to a vehicle cigarette lighter. It is also equipped with a function for direct, ordered storage of the measurement results. A USB communication output can be used to export the data onto a PC in order to process them with the Ground Tester Transfer software. SpecificationsThe C.A 6471 guarantees the reliability of measurements carried out by:
traditional stake-based methods
self-diagnosis when each measurement starts, so that any faults liable to affect the measurements (bad connections or presence of disturbance signals) are indicated
extensive measurement ranges: 0.001 Ω to 100 kΩ
adjustment of the measurement frequency between 41 Hz and 512 Hz (3P & 4P measurements)
The C.A 6471 is equipped with advanced expert calculation functions:
for earth coupling measurements, simply perform the 3 successive measurements required and the tester then calculates the coupling coefficient automatically
for soil resistivity measurements, simply program the distances used for the measurement and the instrument automatically calculates r using the Wenner or Schlumberger methods.
Other specifications:
Power supply: NiMh rechargeable battery with external charger
IP53 protection
Compliant with IEC 61557 -1 -4 -5
Safety: IEC 61010 50V CAT IV
Dimensions: 272 x 250 x 128 mm, 3 kg
Product Brochure :
C.A 6470N/6471
Chauvin Arnoux C.A 6472
Ground Resistance Testers
Product Description
Tester for all types of earth measurements, including pylon earth measurements (with the C.A 6474) - soil resistivity - earth coupling - ground potential - continuity & resistanceThe C.A 6472 can be used for quick, comprehensive surveys of all earthing configurations, offering all the necessary earth measurement functions in a single instrument.When used with the C.A 6474, it can also perform pylon earth measurements, making it a unique but essential tool for diagnostics and maintenance on pylon networks.
The C.A 6472 offers the possibility of analysing the frequency behaviour of the earth connections thanks to its extensive measurement frequency range (41 to 5,078 Hz). The use of a high-frequency measurement signal makes it possible to assess the behaviour of an earthing circuit in the presence of lightning.
Functions:
3P measurement up to 10 kΩ and stray voltages up to 60 V RMS
4P and selective 4P measurement
Earth loop measurement with 2 clamps from 0.01 Ω to 500 Ω
Earth coupling measurement
Soil resistivity measurement: simply program the distances used for the measurement and the tester then calculates r using the Wenner oe Schlumberger methods
Ground potential measurement
Continuity and resistance measurement
Pylon earth measurement with the C.A 6474
Other specifications:
Storage of 512 test results
USB optical link
Ground Tester Transfer PC software to process the stored data
Power supply: NiMh battery with external charger
IP53 protection
IEC 61557 -1 -4 -5
IEC 61010 50V CAT IV
Dimensions: 272 x 250 x 128 mm, 3 kg
Brochure/Specifications Sheet:
https://www.chauvin-arnoux.co.uk/sites/default/files/D00SAJ00.PDF
MX 435D multi-function
Ground Resistance Testers
Description
Multi-function installation testerComplete and lightweight, the MX 435D multi-function tester offers all the essential functions for checking the safety of electrical installations in accordance with the applicable standards: NF C 15-100,EN 61557 (1-2-4-5-6), VDE 0100, IEE 16 th, IEC 64-8, OVE EN-1, RBT MIE. Specially designed for self-employed electricians, installers, certification organizations and maintenance teams, it represents a good compromise in terms of price and performance.Main technical specifications: • Measurements: -Insulation: 0.5 to 199.9 MΩ -Continuity with buzzer: 0.10 to 19.99 Ω -Insulation at 500 V: 0.50 to 199.9 Ω -Earth resistance: 0.10 to 1,999 Ω -Earth loop: 0.10 to 19.99 Ω / 20 to 1,999 Ω-RCD test: 30 mA / 100 mA / 300 mA / 500 mA / 650 mA calibres 1 x IΔn pulse mode-Voltage: 0 to 600 VAC -Current and leakage current (with clamp): 2 A / 200 A ranges• Immediate, error-free connection thanks to colour coding of the terminals and the switch • Fuseless protection against external voltages• Electrical safety: IEC 61010, 300 V CAT III
Citek 50830B Grounding resistance / Soil resistivity tester
Ground Resistance Testers
Product Description:
The Citek 50830B grounding resistance / soil resistivity tester is designed for on-site measurement of grounding resistance, soil resistivity, ground voltage, AC voltage is carefully designed and manufactured using the latest digital micro-processing technology, precise 4-wire method, 3-wire method and simple 2-wire measurement of grounding resistance, import the FFT (Fast Fourier Transform) technology, AFC (automatic frequency control) technology, has a unique anti-jamming capability and ability to adapt to the environment, repeat the test is consistent, to ensure many years measurements of high precision, high stability and high reliability. Widely used in electricity, telecommunications, meteorology, oil, construction, mine and industrial electrical equipment such as grounding resistance, soil resistivity, ground voltage, AC voltage measurement.
The Citek 50830B grounding resistance / soil resistivity tester by the composition of the host, monitoring software, test leads, auxiliary grounding rods, communications lines. Host large LCD display, blue screen backlight, bar graph indication at a glance. Can store 300 sets of data, monitoring software, historical inquiry and online real-time monitoring capabilities, dynamic display, alarm indication, with historical data to read, access, save, report, print and other functions.
Technical Specifications
Base Conditions and Working Conditions
Influence Quantity
Base Condition
Working Conditions
Remark
Ambient Temp
23℃±1℃
-10℃-40℃
----
Ambient Humidity
40%-60%
<80%
----
Working Voltage
9V±0.1V
9V±1.5V
rC、rP
Auxiliary Earth Resistance
<100Ω
<30kΩ
----
Interference Voltage
no
<20V
----
Interference Current
no
<2A
Electrode Distance when measuring R
a>5d
a>5d
----
Electrode Distance when measuring ρ
a>20h
a>20h
----
General Specification
Function
Measurement of 2/3/4-pole earth resistance, soil resistivity, earth voltage, AC voltage
Power Supply
DC 9V(Zi-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours )
Measurement Range
Earth Resistance: 0.00Ω-30.00kΩ
Soil Resistivity: 0.00Ωm-9000kΩm
Measuring Mode
Precise 4-pole measurement, 3-pole measurement, simple 2-pole measurement
Measuring Method
Earth Resistance: rated current change-pole method, measurement current 20mA Max
Soil Resistivity: 4-pole measurement (Wenner method)
Earth Voltage: average rectification(between P(S)-ES)
Test Frequency
128Hz/111Hz/105Hz/94Hz(AFC)
Short-circuit Test Current
AC 20mA max
Open-circuit Test Current
AC 40V max
Test Voltage Wave
Sine wave
Electrode DistanceRange
Can be set 1m-100m
Shift
Earth Resistance: 0.00Ω-30.00kΩ, automatic shift
Soil Resistivity: 0.00Ωm-9000kΩm, automatic shift
Backlight
Blue screen backlight, suitable for dim places
Display Mode
4-digital super-large LCD display, blue screen backlight
Measuring Indicator
During measurement, LED flash indicator, LCD count down display, progress bar indicator
LCD Frame Dimension
128mm×75mm
LCD Window Dimension
124mm×67mm
Dimension
L×W×H: 215mm×190mm×95mm
Standard Test Wire
4 wires: each for red 20m, black 20m, yellow 10m, and green 10m
Simple Test Wire
2 wires: each for red 1.6m and black 1.6m
Auxiliary Earthing Rod
4 rods: Φ10mm×150mm
Measuring Rate
Earth voltage: about 3 times/second
Earth resistance, soil resistivity: about 5 seconds/time
Measuring Times
Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)
Line Voltage
below AC 600V
RS232 Interface
Possess RS232 interface, software supervision, storage data can be uploaded to computer, saved or printed.
Communication Wire
One piece of RS232 communication wire, with length 1.5m
Data Storage
300 sets, “MEM” icon storage indicator, flash display “FULL” icon to indicate storage is full
Data Hold
Data hold function: “HOLD” icon display
Data Access
Data read function: “READ” icon display
Overflow Display
Exceeding measuring range overflow function: “OL” icon display
Interference Test
Recognize interference signal automatically, “NOISE” icon display when interference voltage exceed 5V
Auxiliary Earthing Test
Can measure auxiliary earth resistance, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
Alarm Function
When measuring value exceeds alarm setting value, there is “Toot-toot-toot” alarm hint
Battery Voltage
When battery voltage decreases to about 7.5V, battery voltage low icon will display, reminding to replace battery.
Power Consumption
Standby: about 20mA (Backlight shut off)
Boot and with backlight: about 45mA (25mA without backlight)
Measurement: about 100mA (Backlight shut off)
Weight
Total weight: 4.5kg (including package)
Tester: 1443g (including battery)
Tesing wires: 1560g
Auxiliary earthing rods: 935g (4pcs)
Working Temperature & Humidity
-10℃-40℃, below 80%rh
Storage temperature & humidity
-20℃-60℃, below 70%rh
Overload Protection
Measuring earth resistance: between each interfaces of C(H)-E、P(S)-ES,AC 280V/3 seconds
Insulation Resistance
Over 20MΩ (between circuit and enclosure it is 500V)
Withstanding Voltage
AC 3700V/rms (Between circuit and enclosure)
Electromagnetic Features
IEC61326(EMC)
Protection Type
IEC61010-1 (CAT Ⅲ 300V、CAT IV 150V、Pollution 2), IEC61010-031, IEC61557-1 (Earth resistance), IEC61557-5 (Soil resistivity), JJG 366-2004
Intrinsic error and performance indicators under base conditions
Category
Measurement Range
Intrinsic Error
Resolution
Earth Resistance
(R)
0.00Ω-30.00Ω
±2%rdg±3dgt
0.01Ω
30.0Ω-300.0Ω
±2%rdg±3dgt
0.1Ω
300Ω-3000Ω
±2%rdg±3dgt
1Ω
3.00kΩ-30.00kΩ
±4%rdg±3dgt
10Ω
Soil Resistivity
(ρ)
0.00Ωm-99.99Ωm
According to the precision of R
(ρ=2πaR
a:1 m-100m,
π=3.14)
0.01Ωm
100.0Ωm-999.9Ωm
0.1Ωm
1000Ωm-9999Ωm
1Ωm
10.00kΩm-99.99kΩm
10Ωm
100.0kΩm-999.9kΩm
100Ωm
1000kΩm-9000kΩm
1kΩm
Earth Voltage
AC 0.0-600V
±2%rdg±3dgt
0.1V
Accessories
Tester
1 PC
Tester Bag
1 PC
Auxiliary Earthing Rod
4 PCS
Standard testing Wire
4 wires: each for red 20m, black 20m, yellow 10m, and green 10m
Simple testing Wire
2 wires: each for red 1.6m and black 1.6m
Zinc-manganese Dry Battery
6 PCS (R14S 1.5V)
Monitoring Software Disk
1 Copy
RS232 Communication Cable
1 PC
Manual/Warranty Card/Qualification Certificate
1 Copy